Locomotive Line Series

Serial number Product name Product grade Main uses of the product
 

1

 

125°C irradiated and cross-linked LSZH flame retardant locomotive line

 

H5125

Controls and electricity for railway rolling stock 

cable

 

 

Testing items

 

Unit

H5125
Standard value Typical values
Density g/cm³ ≤1.55 1.48
Hardness A  

97
Tensile strength % ≥9.0 12.5
Elongation at break % ≥150 200
Air thermal aging test ℃xh 158×168
The rate of change in tensile strength % ≤±30 -15.0
Rate of change in elongation at break % ≤±30 +16.0
Oil immersion test 902# oil ℃xh 100×24
The rate of change in tensile strength % ≤±40 27.0
Rate of change in elongation at break % ≤±40 31.0
Oil immersion test 903# oil ℃xh 100×24
The rate of change in tensile strength % ≤±40 28.5
Rate of change in elongation at break % ≤±40 34.0
Oxygen index % ≥28 36
Volumetric resistivity Oh · cm 1.0×1012 1.6×1014
Dielectric strength MV/m ≥18 26
PH value  

≥4.3 6.1
Conductivity μs/ mm| ≤10 1.0
Thermal extension ℃, Mpa.min 200±3,0.2,15
Elongation under load % ≤100 15-30
Permanently deformed after cooling % ≤25 0