Energy storage series cable materials

Serial number Product name Product grade Main uses of the product
1 125°C Irradiated insulation material for energy storage battery connection wires and cables S5125  

Suitable for energy storage battery connection cables

2 125°C energy storage battery connection line cable for irradiation sheathing S3125

 

 

Testing items

 

Unit

S5125 S3125
Standard value Typical values Standard value Typical values
Density g/cm³ ≤1.45 1.35 ≤1.52 1.44
Shaw hardness A 90±2 90 90±2 90
Tensile strength Mpa ≥6.0 11.5 ≥6.0 11.0
Elongation at break % ≥180 300 ≥180 250
Volumetric resistivity Oh · cm 1.0×1014 3.5×1014 1.0×1012 2.3×1013
Air thermal aging test ℃xh 158×168 158×168
The rate of change in tensile strength % ≤±30 +12.0 ≤±30 +12.0
Rate of change in elongation at break % ≤±30 -10.0 ≤±30 -10.0
Acid and alkali resistance test Oxalic acid solution, sodium hydroxide solution 23°Cx168h Oxalic acid solution, sodium hydroxide solution 23°Cx168h
The rate of change in tensile strength % ≤±30 -8.0 ≤±30 -8.5
Elongation at break % ≥100 250 ≥100 190
Low temperature impact embrittlement -40 -40
Failure number individuals ≤15/30 0/30 ≤15/30 0/30
Oxygen index % ≥28 30 ≥28 34
Conductivity μs/ mm| ≤10 2.2 ≤10 2.0
Dielectric strength MV/m  

≥18

 

25

 

≥18

25
PH value  

≥4.3 6.0 ≥4.3 6.3
Thermal extension ℃, Mpa.min 250±3, 0.2,15 250±3, 0.2,15
Elongation under load % ≤100 50 ≤175 50
Permanently deformed after cooling % ≤15 5 ≤15 5